Requirements to Excel Spreadsheet

This simple Python script uses SysIDE and Pandas to load the requirements from SysML v2 file requirements.sysml and store them into an Excel file requirements.xlsx.

Note

Before running this example, make sure you have activated the SysIDE license by running syside-license check according to the instructions in the License Activation section.

Additional Dependencies

This example additionally requires pandas and openpyxl Python packages that can installed using pip. If you are using a virtual environment, ensure that you install the packages into the same .venv where SysIDE Pro is installed.

pip install pandas openpyxl

Example Model

package 'Requirements Example' {
  requirement def 'RQ-01' {
    doc
    /* The fridge shall maintain an internal temperature between 1°C and 4°C (34°F and 39°F) for food preservation. */
  }
  requirement def 'RQ-02' {
    doc
    /* The freezer compartment shall maintain a temperature of -18°C (0°F) or below for long-term storage of frozen items. */
  }
  requirement def 'RQ-03' {
    doc
    /* The fridge shall meet or exceed Energy Star efficiency standards, consuming no more than 400 kWh per year. */
  }
  requirement def 'RQ-04' {
    doc
    /* The fridge shall have an automatic defrosting system to prevent the buildup of frost inside the freezer. */
  }
  requirement def 'RQ-05' {
    doc
    /* The fridge doors shall have magnetic gaskets to ensure an airtight seal and prevent energy loss. */
  }
  requirement def 'RQ-06' {
    doc
    /* The operational noise of the fridge shall not exceed 40 dB(A) under normal conditions. */
  }
  requirement def 'RQ-07' {
    doc
    /* The fridge shall provide adjustable shelves to accommodate a variety of food sizes and configurations. */
  }
  requirement def 'RQ-08' {
    doc
    /* The fridge shall include a digital temperature control system with an accuracy of ±1°C. */
  }
  requirement def 'RQ-09' {
    doc
    /* The fridge shall feature a humidity-controlled drawer to extend the freshness of perishable items like fruits and vegetables. */
  }
  requirement def 'RQ-10' {
    doc
    /* The fridge shall be equipped with energy-efficient LED lighting that illuminates all compartments. */
  }
  requirement def 'RQ-11' {
    doc
    /* The fridge shall have a built-in water and ice dispenser capable of dispensing both cubed and crushed ice. */
  }
  requirement def 'RQ-12' {
    doc
    /* The fridge shall support Wi-Fi connectivity, enabling remote temperature monitoring and control via a mobile app. */
  }
  requirement def 'RQ-13' {
    doc
    /* The fridge shall include an audible alarm system to notify users if the door is left open for more than 2 minutes. */
  }
  requirement def 'RQ-14' {
    doc
    /* The fridge shall provide a minimum storage capacity of 20 cubic feet, including separate compartments for dairy, meat, and produce. */
  }
  requirement def 'RQ-15' {
    doc
    /* The fridge shall include a backup battery or auxiliary power system capable of maintaining critical temperatures for at least 4 hours during a power outage. */
  }
}

Example Script

import pathlib
import pandas as pd
import syside

EXAMPLE_DIR = pathlib.Path(__file__).parent
REQUIREMENTS_EXCEL = EXAMPLE_DIR / "requirements.xlsx"
REQUIREMENTS_SYSML = EXAMPLE_DIR / "example_model.sysml"


def main() -> None:
    # Load model.
    model, diagnostics = syside.load_model([REQUIREMENTS_SYSML])

    assert not diagnostics.contains_errors(warnings_as_errors=True)

    # Populate the data frame.
    data = []
    for requirement in model.nodes(syside.RequirementDefinition):
        for doc in requirement.documentation.collect():
            print(f"Adding requirement {requirement.declared_name}: {doc.body}")
            data.append(
                {
                    "ID": requirement.declared_name,
                    "REQUIREMENT": doc.body,
                }
            )
    df = pd.DataFrame(data)

    # Save the dataframe to the Excel file.
    df.to_excel(REQUIREMENTS_EXCEL, index=False)


if __name__ == "__main__":
    main()

Output

Adding requirement RQ-01: The fridge shall maintain an internal temperature between 1°C and 4°C (34°F and 39°F) for food preservation.
Adding requirement RQ-02: The freezer compartment shall maintain a temperature of -18°C (0°F) or below for long-term storage of frozen items.
Adding requirement RQ-03: The fridge shall meet or exceed Energy Star efficiency standards, consuming no more than 400 kWh per year.
Adding requirement RQ-04: The fridge shall have an automatic defrosting system to prevent the buildup of frost inside the freezer.
Adding requirement RQ-05: The fridge doors shall have magnetic gaskets to ensure an airtight seal and prevent energy loss.
Adding requirement RQ-06: The operational noise of the fridge shall not exceed 40 dB(A) under normal conditions.
Adding requirement RQ-07: The fridge shall provide adjustable shelves to accommodate a variety of food sizes and configurations.
Adding requirement RQ-08: The fridge shall include a digital temperature control system with an accuracy of ±1°C.
Adding requirement RQ-09: The fridge shall feature a humidity-controlled drawer to extend the freshness of perishable items like fruits and vegetables.
Adding requirement RQ-10: The fridge shall be equipped with energy-efficient LED lighting that illuminates all compartments.
Adding requirement RQ-11: The fridge shall have a built-in water and ice dispenser capable of dispensing both cubed and crushed ice.
Adding requirement RQ-12: The fridge shall support Wi-Fi connectivity, enabling remote temperature monitoring and control via a mobile app.
Adding requirement RQ-13: The fridge shall include an audible alarm system to notify users if the door is left open for more than 2 minutes.
Adding requirement RQ-14: The fridge shall provide a minimum storage capacity of 20 cubic feet, including separate compartments for dairy, meat, and produce.
Adding requirement RQ-15: The fridge shall include a backup battery or auxiliary power system capable of maintaining critical temperatures for at least 4 hours during a power outage.

Download